1-888-546-0524
find us on facebook follow us on twitter connect on linked in read our blog connect on google plus

AC Fans

Pelonis Technologies provides alternating current (AC) fans in a large range of configurations for a variety of customer applications. Count on PTI's fans for safe, reliable features not found on competitors' fans: unique, multi-blade designs to increase airflow, high-quality long-life bearings for quiet operation, and safety features that protect against high temperatures, vibration, dust and water, designed to meet the most stringent of standards. (All PTI fans meet UL, cUL, TUV, and CE certification. RoHS compliant.)

Various fans are offered by PTI. These include Metal Blade, Plastic Frame, Reverse/High Air Flow, High Air Flow, Low Air Flow, Reverse/Standard and Standard models. The fans come in a range of sizes. Optional tachometer or rotation detectors for added safety are available as well.

AC Fan Quick Reference Table

mm

inches

Series

Description

CFM

inH2O

dBA

254 x 89 10.0 x 3.5 RA2589-C High Air Flow 423-850 0.35-0.83 52-88
222 x 60 8.7 x 2.4 RA2260-C High Air Flow 430-485 0.71-0.94 59-62
172 x 51 6.8 x 2.0 RA1725-C High Air Flow 250-293 0.63-0.79 56-61
172 x 51 6.8 x 2.0 RA1725 Standard 133-187 0.15-0.55 45-55
172 x 150 x 51 6.8 x 5.9 x 2.0 RA1751-C High Air Flow 250-293 0.63-0.79 56-61
172 x 150 x 51 6.8 x 5.9 x 2.0 PM1751-7 Standard 186-240 0.22-0.37 48-53
172 x 150 x 51 6.8 x 5.9 x 2.0 PM1751-5 Low Air Flow 161-228 0.32-0.53 40-49
172 x 150 x 38 6.8 x 5.9 x 1.5 RA1738-C High Air Flow 166-198 0.66-0.77 57-61
162 x 150 x 55 6.8 x 5.9 x 2.2 RA1555-C High Air Flow 250-293 0.63-0.79 56-61
162 x 150 x 55 6.8 x 5.9 x 2.2 RA1555 Standard 123-181 0.14-0.52 45-56
162 x 150 x 38 6.8 x 5.9 x 1.5 RA1538-C High Air Flow 166-198 0.66-0.77 57-61
127 x 127 x 38 5.0 x 5.0 x 1.5 RA1278-C High Air Flow 117-151 0.28-0.51 42-49
127 x 127 x 38 5.0 x 5.0 x 1.5 RA1278 Standard 65-130 0.10-0.27 30-46
127 x 127 x 38 5.0 x 5.0 x 1.5 RA1278(P5B) Plastic Frame 65-121 0.10-0.27 30-46
120 x 120 x 38 4.7 x 4.7 x 1.5 RA1238-C High Air Flow 104-130 0.26-0.49 39-47
120 x 120 x 38 4.7 x 4.7 x 1.5 RA1238-C Reverse/High Air Flow 93-126 0.14/0.42 43-49
120 x 120 x 38 4.7 x 4.7 x 1.5 RA1238 Reverse/Standard 70-113 0.08/0.26 35-50
120 x 120 x 38 4.7 x 4.7 x 1.5 PM1238-7 Standard 85-108 0.17-0.28 38-45
120 x 120 x 38 4.7 x 4.7 x 1.5 PM1238-5 Low Air Flow 72-98 0.11-0.30 36-45
120 x 120 x 38 4.7 x 4.7 x 1.5 RA1238(5BM) Metal Blade 65-96 0.11-0.28 37-45
120 x 120 x 38 4.7 x 4.7 x 1.5 RA1238(P5B) Plastic Frame 61-94 0.11-0.35 36-44
120 x 120 x 25 4.7 x 4.7 x 1.0 RA1225-C High Air Flow 76-103 0.18-0.35 38-46
120 x 120 x 25 4.7 x 4.7 x 1.0 PM1225-7 Standard 51-67 0.10-0.17 31-38
92 x 92 x 38 3.6 x 3.6 x 1.5 RA9238-C High Air Flow 34-56 0.13-0.30 26-36
92 x 92 x 38 3.6 x 3.6 x 1.5 RA9238 Standard 38-50 0.15-0.24 26-35
92 x 92 x 25 3.6 x 3.6 x 1.0 RA9225-C High Air Flow 39-50 0.13-0.24 27-34
92 x 92 x 25 3.6 x 3.6 x 1.0 PM9225-7 Standard 24-29 0.10-0.10 20-24
80 x 80 x 38 3.2 x 3.2 x 1.5 RA8038-C High Air Flow 22-32 0.12-0.24 24-31
80 x 80 x 38 3.2 x 3.2 x 1.5 PM8038-7 Standard 17-26 0.06-0.16 19-30
80 x 80 x 25 3.2 x 3.2 x 1.0 RA8025-C High Air Flow 21-30 0.10-0.21 23-31
80 x 80 x 25 3.2 x 3.2 x 1.0 PM8025-7 Standard 12-19 0.05-0.11 20-27

Standard Specifications

OPERATION VOLTAGE: ±10% of rated voltage
STORAGE TEMPERATURE: -40°C to +80°C @65% relative humidity
INSULATION RESISTANCE: 100 Mohm Min @DC 500V
DIELECTRIC STRENGTH: AC 1500V for 3 sec (<0.5mA allowable between lead and frame).
NOISE: Measured at rated voltage at 1 meter distance in an anechoic chamber with a background noise of 16dBA max.
VIBRATION: JIS C0040 amplitude 1.5mm frequency 10-55Hz, 1 hr per axis: X, Z, Y.
SHOCK: JIS C0041 acceleration 100G, duration 6ms per axis: X, Z, Y.
LIFE: Life expectancy is 50,000 hours for ball bearings or 30,000 hours for sleeve bearings @°25C, 65% ±20% relative humidity continuous operation.
SAFETY: Designed to meet UL, cUL, TUV, and CE certification. RoHS compliant.
INSULATION: Class B

Static Pressure Conversion Table

Pa (=N/m2)

mmH2O = mmAq

inH2O

Kgf/cm2

bar

1 1.0197 x 10-1 4.017 x 10-3 1.0197 x 10-5 1 x 10-5
9.70665 1 3.939 x 10-2 1 x 10-4 9.80665 x 10-5
1.3332 x 102 1.3619 x 10 1 1.3595 x 10-3 1.3332 x 10-3
9.80665 x 104 104 3.937 x 102 1 9.80665 x 10-1
1 x 105 1.0197 x 104 4.018 x 102 1.01972 1

Air Flow Conversion Table

m3/min

CFM

L/s

L/min

1 3.531 x 10 1.666 x 10 1 x 103
2.831 x 10-2 1 4.720 x 10-1 2.831 x 10
6 x 10-2 2.118 1 6 x 10
1 x 10-3 3.531 x 10-2 1.666 x 102 1

Fahrenheit/Celsius/Kelvin Conversion Table

Fahrenheit to Celsius

Celsius to Fahrenheit

Celsius to Kelvin

°C = (5/9) * (°F-32) °F = (°C * (9/5)) +32 K = °C + 273.15

Value-Added Features and Benefits

We offer additional features that provide value-added benefits to our customers that are not commonly found in competitive products:

  • Unique multi-blade designs increase airflow
  • High-quality bearings ensure quiet operation and longer life
  • Impedance protection ensures safe operation at high temperatures
  • Thermal protection reduces fan overheating at high temperatures
  • Built-in locked rotor protection increases fan life
  • Tachometer output monitors fan speed and reduces fan failure
  • Rotation detection determines fan operation and reduces failure

Please contact one of our knowledgeable technical sales consultants to discuss your needs in detail.